APC SMART-UPS RT 8000VA RM 230V PDF

Automatic internal bypass supplies utility power to the connected loads in the event of a UPS power overload or fault. Scalable runtime allows additional run time to be quickly added as needed. Intelligent battery management maximizes battery performance, life, and reliability through intelligent, precision charging. Hot-swappable batteries ensures clean, uninterrupted power to protected equipment while batteries are being replaced. For more information go to www. See more tech specs See less.

Author:Nikorr Totilar
Country:India
Language:English (Spanish)
Genre:Love
Published (Last):15 June 2004
Pages:213
PDF File Size:15.40 Mb
ePub File Size:4.58 Mb
ISBN:979-4-89742-280-4
Downloads:47511
Price:Free* [*Free Regsitration Required]
Uploader:Nikokora



High density, double-conversion on-line power protection with scalable runtime. The total load power draw entered exceeds the maximum value for this product W. Please enter load to see estimated run time. Please enter load to see calculated "Max.

Capacity Used". Find a Reseller. Product Overview Technical Specifications. Run time for load W. Run time for load. Enter the total load power draw of all devices to be protected by the UPS here.

Based on the value entered we will estimate the run time that you will have during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down. Capacity Used. The maximum percentage of UPS capacity used to support your specified load. Output power capacity 8. Rack Height 6U. Nominal Output Voltage V. Provides early-warning fault analysis on batteries enabling timely preventive maintenance.

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. Text and mimic diagrams that display modes of operation, system parameters and alarms. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.

Scalable runtime Allows additional run time to be quickly added as needed. Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Flash upgradeable firmware Install maintenance releases of firmware remotely using FTP.

Plug-and-Play external batteries Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS. LED status indicators Quickly understand unit and power status with visual indicators. Serial connectivity Provides management of the UPS via a serial port.

Network manageable Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded. Audible alarms Provides notification of changing utility power and UPS power conditions.

Disconnected battery notification Warns when a battery is not available to provide backup power. Predictive failure notification. Provides early-warning fault analysis ensuring proactive component replacement. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR.

Cold-start capable Provides temporary battery power when the utility power is out. Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used. Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. Resettable circuit breaker Easy recovery from overloads; no need to replace a fuse. Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling. Marketing Features. Low operating and maintenance costs with proven reliability and intelligent battery management. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging.

Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Avoids costly power problems by keeping your IT equipment and data protected and available. Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.

Peace of mind that comes with full equipment compatibility and reliability of a leader Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected PFC power supplies. Network manageable via serial, USB or Ethernet. Technical Specifications Print Technical Specification. Max Configurable Power Watts 8. Other Output Voltages , Load Crest Factor 3 : 1.

Topology Double Conversion Online. Waveform type Sine wave. Bypass Internal Bypass Automatic and Manual. Input frequency 40 - 70 Hz auto sensing. Input voltage range for main operations - V. Input voltage adjustable range for mains operation - half load , - half load V. Other Input Voltages , , , Battery type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof. Typical recharge time 1.

Expected Battery Life years 3 - 5. RBC Quantity 2. Extendable Run Time 1. Battery Volt-Amp-Hour Capacity Runtime View Runtime Graph. View Runtime Chart. Efficiency View Efficiency Graph. Control panel Multi-function LCD status and control console. Audible Alarm Audible and visible alarms prioritized by severity. Surge Protection and Filtering. Surge energy rating Joules.

Maximum Height MM, Maximum Width MM, Maximum Depth MM, Net Weight Shipping weight Shipping Height MM, Shipping Width MM, Shipping Depth MM, Color Black.

Units per Pallet 1. Operating Elevation meters. Storage Elevation meters. Audible noise at 1 meter from surface of unit Online thermal dissipation Protection Class IP Standard warranty 3 years repair or replace excluding battery and 2 years for battery. Sustainable Offer Status. RoHS Compliant. View Cart. Continue Shopping Checkout.

ARTUR BANIEWICZ SMOCZY PAZUR PDF

APC Smart-UPS SRT 8000VA RM 400/230V (SRT8KRMXLI)

For Immediate delivery requirement contact sales team. Images are for illustration purposes only and may differ from actual product. High density, double-conversion on-line power protection with scalable runtime. Peace of mind that comes with full equipment compatibility and reliability of a leader. Low operating and maintenance costs with proven reliability and intelligent battery management. Avoids costly power problems by keeping your IT equipment and data protected and available.

IMPARATUL MUSTELOR WILLIAM GOLDING PDF

SURT8000RMXLI

High density, double-conversion on-line power protection with scalable runtime. The total load power draw entered exceeds the maximum value for this product W. Please enter load to see estimated run time. Please enter load to see calculated "Max. Capacity Used". Sign in Create Account.

Related Articles